Company


July 26, 2018

How to Troubleshoot an Unsupported Deck Edge

Have you ever received error message 2054 when modeling in RISAFloor?

This error means that the program has detected an unsupported deck edge, but often there is confusion about what this means.  RISAFloor expects that you have either a beam or a wall parallel to every deck edge in your model. This allows for the deck to have a supporting element around its entire perimeter.

To troubleshoot the error message above, first turn on the graphical view of your manually applied decks using the Show Deck Assignment – w/o Default toggle.

Once you have your decks displayed, you can zoom in on the edges to verify that there are parallel beams and/or walls under each edge.

Once you find the culprit, you can simply redraw the deck to align with the supporting elements or model in a weightless dummy member to support the deck and carry the load back to the true supporting members.


Tags: ,

This entry was posted by RISA News on Thursday, July 26th, 2018 at 11:00 am and is filed under Technical Solutions. You can follow any responses to this entry through the RSS 2.0 feed. Both comments and pings are currently closed.