The member capacity for axial compression and for flexure is dependent on the spacing of elements which provide bracing along the length of a member. By default the program assumes that no bracing is provided along the length of the Physical Member. This is represented by the condition where the unbraced length field is shown as empty/blank.

Note: If bracing is not provided at each end of the physical member then the assumption that the unbraced length equals the physical member length can be unconservative. The program allows you to specify an unbraced length greater than the physical member length to address this situation.

You may specify unbraced lengths as a fixed distance or by using RISA's Unbraced Length Commands. The unbraced lengths are:

The unbraced lengths that are used for member capacity calculations are listed in the Member Detail report after solution.

Note: Specifying bracing via unbraced lengths does not provide physical bracing to the model for analysis. It only affects the member capacity calculated for code checks. See the example below.

Lb Values (Lb, Lu, Le)

The Lb values: Lbyy andLbzz,represent the distance between points which brace the member against Flexural (column-type) Buckling about the member's local y and z axes, respectively. Lb bracing prevents the entire member from moving laterally (perpendicular to its own axis). These Lb values are used to calculate slenderness ratios (KL/r) for both directions, which are used in the calculation of member axial compression capacity.

Lcomp Values (Lcomp, Le-bend)

The Lcomp values, Lcomp-top and Lcomp-bot, represent the distance between points which brace the top or bottom flange of the member against Lateral-Torsional (beam-type) Buckling. These Lcomp values are used to calculate the member's flexural (bending) capacity. Where the top flange of the member is in compression due to bending, Lcomp-top is used. Where the bottom flange of the member is in compression due to bending, Lcomp-bot is used. Lcomp bracing prevents the member's flange from moving laterally (perpendicular to the member's axis).

Members which experience a moment reversal along their length (such as fixed-end or continuous members) have compression in both the top and bottom flange (although not simultaneously). The program uses the appropriate Lcomp (top or bottom) based on moment direction to calculate the bending capacity at each internal section along the member.

The top flange is the flange on the positive local y-axis side of the member. Therefore if a beam if rotated 180 degrees about its own axis (flipped upside down) the "top" flange will actually be facing downwards.

Note: Concrete members are not checked for lateral-torsional buckling, so Lcomp is not used for concrete.

L-torque

The L-torque value represents the distance between points which restrain the member against twisting about its own axis. This value is used to calculate the member's Torsional Buckling and Flexural-Torsional Buckling capacity. These limit states affect the member's axial compression capacity.

Note:

Automated Unbraced Length Commands

Aside from leaving the unbraced length blank or inputting a fixed distance, you can harness the program's ability to use a limited intelligence for determining unbraced lengths. In order to do this you can simply type in the name of the Unbraced Length Commands into the unbraced length field. If a valid command word is used then the program will accept and display that command in lieu of a distance value.

Some member types are pre-populated with an Unbraced Length Command when they are created. Below is a list of the commands which may be used:

Segment

When this command is used, all Nodes which fall along the length of the physical member are assumed to provide bracing. If Nodes are not evenly spaced along the member then an unbraced length is calculated for each "segment". A segment is defined as the distance between adjacent Nodes. In the example below, the member is defined as one physical member spanning from N1 to N2. The intermediate node N3 is considered as a brace point when Segment is specified for this member. Therefore the forces which occur in Segment 1 will be compared against a capacity calculated using Lb1, and the forces occurring in Segment 2 will be compared against a capacity calculated using Lb2.

When using the Segment command the program will assume that each node along the length of the member can act as a brace location regardless of whether any bracing or restraint exists. In the example above this will result in an unconservative member capacity if no bracing will be supplied at N3 in real life.

Lbyy

This command is only available for Lcomp-top and Lcomp-bot. When this command is used, the value entered for Lbyy will also be used for Lcomp.

Click on image to enlarge it

In the example below, Case C, the Lbyy command could be appropriately be used in the Lcomp-top field. In the example below, Case D, the Lbyy command could be appropriately used in both Lcomp fields. It would not be appropriate to use the Lbyy command for Case A or Case B below.

Floor

For RISA-3D models which are linked to RISAFloor models, if an unbraced length is set in RISAFloor, it is listed as Floor in RISA-3D spreadsheets. This indicates that the unbraced length was set in RISAFloor for all locations along the length of the member, and those same values are being used in the RISA-3D model.

In the example below, the fixed-end beam M2 is using the Framing command for Lcomp-bot in RISAFloor.

When this beam is brought into RISA-3D, the RISA-3D member properties show that Lcomp-bot is referencing RISAFloor (Floor).

After the model is solved you can confirm in the Member Detail Report that the RISAFloor unbraced length is being used. The maximum code check occurs at 0 feet from the i-end of the member. Because this is a fixed-fixed beam, the bottom flange is in compression there so Lcomp-bot is used instead of Lcomp-top.

Material Specific Behavior

Hot Rolled Steel

Cold Formed Steel

In general, the unbraced lengths for Cold Formed bending checks are based on the Lcomp value and axial checks are based on Lb values. Below describes more specifics based on the AISI 2012 code.

 

Lateral Torsional Buckling (AISI C3.1.2)

Lt = Lcomp

Lcomp is the unbraced length for the flange that’s in bending compression at that section (either Lcomp_top or Lcomp_bot).

This applies to all shapes and all AISI codes.

Note: Older Versions of RISA-3D (v12 and older)

Lt= smaller of Lbyy and Lcomp

 

When Lateral Torsional Buckling governs over local buckling, the display of the Seff in the Detail Report will report the Sc which is the elastic section modulus of effective section calculate relative to the extreme compression fiber at Fc.

 

Distortional Buckling (AISI C3.1.4)

Lm=Lcomp

Lcomp is the unbraced length for the flange that’s in bending compression at that section (either Lcomp_top or Lcomp_bot).

 

Axial Strength (AISI C4.1)

L= Could be Lbyy or Lbzz, whichever gives the larger of (KL/r)yy or (KL/r)zz

 

Flexural Torsional Buckling or Torsional Buckling (AISI C4.1.2)

Lt= L-Torque

 

Note: Older Versions of RISA-3D (v12 and older)

Lt= smaller of Lbyy and Lcomp

 

Distortional Buckling (AISI C4.2)

Lm= L-Torque

Concrete

Wood

Aluminum

For additional advice on this topic, please see the RISA Tips & Tricks webpage at risa.com/post/support. Type in Search keywords: Unbraced Lengths.

K Factors (Effective Length Factors)

Effective Length Factors (K) are recommended or required for some design codes. The effective length factor allows you to adjust the unbraced length for Flexural Buckling as a simplified method of accounting for buckling effects.  Kyy is a modifier factor for Lbyy. Kzz is a modifier factor for Lbzz.

If the K Factor field is left blank/empty then it is taken as 1.0, thereby not affecting the unbraced length.

If a value is entered for a K Factor, that value will be used for the entire length of the physical member. If an entry is not made (left blank), the value will internally default to '1' for that member

Note: K-torque for Torsional or Flexural-Torsional Buckling is always be assumed t o be 1.0, except for Aluminum design where it is taken as the lesser of Kyy or Kzz.

K Approximation Feature

RISA-3D is able to approximate the recommended K values for a member based on the member's sway condition and end release configuration. The K-factor approximation is based on AISC 360-10, Table C-A-7.1. To access this feature you must be in the Members spreadsheet, on the tab which shows the unbraced lengths. Click theK-Factor icon on the Spreadsheets menu.

Click on image to enlarge it

The following table gives the values the program calculates for various conditions.

Table Case End Conditions Sidesway? K-Value

(a)

Fixed-Fixed

No

.65

(b)

Fixed-Pinned

No

.80

(c)

Fixed-Fixed

Yes

1.2

(d)

Pinned-Pinned

No

1.0

(e)

Fixed-Free

Yes

2.1

(f)

Pinned-Fixed

Yes

2.0

RISA-3D recognizes a pinned boundary condition for the K approximation for a full pin, i.e. if all the rotations in the boundary condition are released. If any of the rotations in a boundary condition are restrained, the boundary condition is considered "fixed" for the K factor approximation.

Any configuration not described here is given the default value of '1.0'.

If any value that influences these K values is changed, the K factor approximation should be redone. For instance, if you have RISA-3D approximate K factors, then change some of the member end release designations, you should redo the K factor approximations.

Remember that the K factors are approximations and you should check to make sure you agree with all K factors RISA-3D assigns. You can always override a K factor after an approximation by directly entering the value that you want in the appropriate field. Keep in mind that a subsequent approximation will overwrite any manually input values so you will need to override the approximation each time it is performed.

Click on image to enlarge it

Limitation:

RISA-3D will currently neglect the influence of adjoining framing members when those members are connected at a joint that also has degrees of freedom restrained by boundary conditions. For example, suppose a column and beam member connect at a joint that is restrained for translation in all directions (i.e. the joint is "pinned"). The K factor approximation will neglect the beam member when it calculates the K factor for the column and visa-versa. The effect will be that the ends of the members at that joint will be seen as "pinned" and not "fixed" for the K factor approximation.

Sway Flags

The Sway Flags indicate whether the member is to be considered subject to sidesway for bending about its local y and z axes. The y sway field is for y-y axis bending and the z sway field is for z-z axis bending. Click on the field to check the box and indicate that the member is subject to sway for that particular direction, or leave the entry blank if the member is braced against sway. These sway flags influence the calculation of the K factors as well as the Cm and Cb factors.