Warning Log

The Warning Log Spreadsheet provides you with a record of any warnings or errors that occurred during the solution of your model. The log should be reviewed for warnings or errors that would affect the design of your structure.  The error log reports back the item label for which the error occurred.

You can view the warning log by clicking on the Spreadsheets menu item and then clicking on the Warning Log selection.

Pressing the ? hyperlink will open the help file to give further explanation on this item.

Here is a common warning which could require some additional explanation:

Sum of reactions is not equal to the sum of the loads (LC xx)! Check for any small rigid links or fixed boundary conditions.

When the solution is complete, the program checks the sum of the reaction forces in each direction if this is more than 0.1% different from the sum of the applied loads, then this warning message will be displayed. The most common causes for this warning message are the following: 

For additional advice on this topic, please see the RISA Tips & Tricks webpage at risa.com/post/support. Type in Search keywords: Sum of Reactions.

Here is a table containing all possible warnings, the cause, and possible solutions:

======= =======
Warning Number Warning Log Message Cause Solution
WARNING 41001 Web Slenderness > 70e. Web Buckling NOT checked for Shear Capacity.

British Hot Rolled Steel Design has been requested for a Hot Rolled Steel HHS Tube, Channel, or WT shape that has a very slender web. The current design code does not address web buckling as a failure state for shapes other than Wide Flange Members.

See if a code revision now provides guidance on checking web buckling for Tubes, Channels, or WT shapes.

WARNING 41003 The rebar does not exist. No Capacity Calculated. This message means that a user defined reinforcement profile has resulted in a member with zero capacity (and zero reinforcement) at the described location. Revise the user defined reinforcement so that it is present at all locations along the member's length.
WARNING 41005

Span length is less than 1 foot. No design for this span.

RISA uses span information to perform concrete member design and rebar optimization. When a member spans less than 1 foot from support to support then the program cannot perform this design. Increase the span to a length greater than 1 foot, or ignore design of this member in this short segment.
WARNING 41007

Composite design not done : Beam is continuous.

The composite beam has fixed ends, or passes as a continuous member over a support. This resulted in a negative bending moment on the beam, which would place the concrete slab in tension. RISA cannot perform a composite design when the slab is in tension. Modify the beam's end releases to be pinned, or eliminate a midspan support under the beam. Otherwise, change the beam to be non-composite. For a T-beam member in RISA-3D seeing negative bending, the flanges will be ignored.
WARNING 41009 Unable to provide min steel (As,min) per Model Settings. A minimum area of steel was specified in the Model Settings. However, the cross section size, and the rebar spacing and cover requirements prevent enough rebar from being placed to meet that area of steel requirement. Increase the cross section size of the member so that more steel can be placed, or lower the minimum area of steel requirement in the Model Settings.
WARNING 41011 The tensile strain in steel is less than 0.004 The arrangement and amount of reinforcing steel is such that if the member fails it will fail in a brittle manner (Compression Controlled Section)). This is not allowed, per ACI 318-14, Sections 7.3.3.1, 8.3.3.1, 9.3.3.1 (ACI 318-11 Section 10.3.5) The quantity and arrangement of rebar is such that the rebar is not yielding prior to a concrete failure. Change the dimensions of the cross section of the concrete or alter the rebar design rules such that the rebar yields first.
WARNING 41012 The tensile strain in steel is less than 0.005 The arrangement and amount of reinforcing steel is such that if the member fails it might fail in a brittle manner (Transition Section). The strength reduction factor was reduced according to ACI 318-14, Section 21.2.2 (ACI 318-11 Section 10.3.4) This does not indicate a failure. However, the full strength of the section is not being reached. To increase the strain (and therefore increase the strength), change the dimensions of the cross section of the concrete or alter the rebar design rules such that the rebar yields first.
WARNING 41021 More than 200 bars not allowed. The concrete column solver used by RISA for our direct integration solution has an internal limit of 200 flexural bars per concrete column. This limit has been exceeded for this member. If using a custom rebar layout, reduce the number of bars. If doing rebar optimization, use a larger minimum bar size so the program will use fewer bars.
WARNING 41023 Optimize concrete beam solver error. The concrete beam solver has encountered an error. Contact RISA Support and send your model so that this error can be resolved.
WARNING 41025 Column/Beam Cover Value too large. 25% of member depth used instead. The program's concrete solver was not designed to accommodate very large cover values relative the member depth/width. Therefore a maximum cover value of 25% of the member's dimension in that direction was used instead of the cover value specified in the rebar design rules. Modify the member size or the cover dimension so that the cover dimension is no more than 25% of the member dimension.
WARNING 41027 Unable to Iterate Phi for a Given Rebar Strain. For the ACI-318 2002 Concrete Code and later, the Phi value for axial/flexural loading is based on the concrete strain, and must be iterated for the Load Contour method. This iteration process has failed for this particular member and load. Send this model to RISA so we can review the conditions under which the value of Phi could not be calculated.
WARNING 41029 Member/Wall is slender and can sway, but P-Delta Analysis was NOT run. A slender concrete column or concrete wall panel has a Sway flag set in its Design Parameters , however a P-Delta analysis was not run in 1 or more Load Combinations that are set to do Concrete Design, so the expected amplifying effects were not calculated. On the Load Combinations spreadsheet, set the PDelta value to be "Y" or "C" so that a P-Delta analysis is run for the Load Combinations that are flagged to do Concrete Design. Alternately, if the member or wall cannot sway, remove the Sway flag.
WARNING 41031 Slender Compression Failure (Pu > .75Pc). No Slender calculations done. The axial compression exceeds 75% of the Euler Buckling capacity of the member. This means that the member is prone to column-type buckling, and it causes ACI 318-14/19, Eqn 6.6.4.5.2 (ACI 318-11 Eqn 10-12) to go to infinity (representing a column buckling failure) Decrease the axial compression load on the member, or increase the cross section size, or decrease the unbraced length of the member.
WARNING 41034 KL/r > 100 for this compression member. See ACI 318-05 Section 10.11.5 ACI 318-05 and earlier concrete codes allowed the moment magnification procedure to be used in lieu of a second order analysis. RISA uses the moment magnification procedure for these codes. This was limited to members with a slenderness less than 100. ACI 318 08/11/14 do not have this limitation because of the P-Delta analysis requirement. Increase the cross section size, or decrease the unbraced length of the member. Alternatively, use a newer version of the code where this requirement no longer exists.
WARNING 41042 KL/r > 120 for this compression member. See AS 10.5.1 : 2001 AS 3600-2001, Section 10.5.1 prohibits the slenderness of a member from exceeding 120 unless a "rigorous analysis" is performed. RISA does not perform that rigorous analysis, so therefore this limit must be enforced. Increase the cross section size, or decrease the unbraced length of the member.
WARNING 41044 H/r > 410 for this compression member. See NTC-DF2004 1.4.2.2 NTC-DF2004, Section 1.4.2.2.b states that a non-linear second order analysis be performed if the slenderness exceeds 410. RISA does not perform that type of analysis, so therefore this limit must be enforced. Increase the cross section size, or decrease the unbraced length of the member.
WARNING 41046 Failed to satisfy minimum rebar (Temperature + Shrinkage) requirement. The concrete rebar optimization was unable to place enough rebar to satisfy the requirements for temperature and shrinkage per ACI 318-14/19, Sections 8.6.1.1 and 24.4.3.2 (ACI 318-11 Section 7.12.2.1) Change the cross section size or change the rebar optimization parameters in the Design Rules so that enough rebar can be placed to meet this code requirement.
WARNING 41052 Reinforcement is failing. See detail report for more information. The program was unable to place enough rebar to meet strength requirements, or the explicit rebar provided was insufficient. See the detail report. It is likely that the concrete dimensions need to be changed, or the rebar requirements need to be changed in the Design Rules
WARNING 41076 Tapered Member has a Fy greater than 55 ksi. AISC Design Guide #25 is used for the design of tapered members, however the design guide is limited to members with a yield stress not exceeding 55 ksi per Section 1.2.1. Therefore no design can be done for this member. Use a material with a lower yield stress for this member, or specify a design code which accommodates this material strength.
WARNING 41077 bf < h/7 for some of the unbraced length. AISC Design Guide #25 is used for the design of tapered members, however the design guide is limited to members with a flange width not less than 7 times the web depth per Section 1.2.7. Therefore no design can be done for this member. Use a member with a wider flange or a more shallow web. Or specify a design code which accommodates a member with these dimensions.
WARNING 41082 Could not use 2 Minimum Flexural Bars. No Code Check Possible. The program cannot design members with less than two bars. The member size, cover, spacing requirements, bar size, and stirrup size prevent two bars from being placed in this member. Alter the cross section dimension, or modify the rebar design rules so that two bars can fit.
WARNING 41083 Can't add more new rebar layout name(s). Default layout is restored. When opening a model file that contains 1 or more custom rebar layouts that do not exist in the current library of custom rebar layouts, the program tries to add the layouts from the model file to the copy of the library in memory. If adding another layout would exceed the maximum number of layouts, no further layouts are added and members that referenc a layout that could not be added will have their layout selection set to the default value. Remove any unneeded rebar layouts from the current program library of custom rebar layouts to make room so the new layouts can be read in. Alternately, temporarily rename the custom rebar layout library file so that no custom rebar layouts are read in when the program starts up and then the model file will read in with all its rebar layouts.
WARNING 41084 Invalid moving load pattern referenced in this file. The pattern was not found in the current moving load library. The moving load pattern is saved on each user's computer and it is not carried with the model. Locate the moving load library from the original model's computer and place it in the RISA folder.
WARNING 41085 The BLC entry for a load combination is not valid. This BLC entry has been cleared, check your combinations! The Load Combinations spreadsheet is referencing a Basic Load Case that does not exist. This is not allowed, so that Basic Load Case was removed from the Load Combinations. Carefully review the Load Combinations spreadsheet to ensure that it is referencing all of the correct Basic Load Cases.
WARNING 41086 Invalid Shape Name. Previous entry for this field was restored. There are shape names that not allowed to be used in RISA because they conflict with default names or do not follow the naming convention rules. Try to rename the shape using a different name or review the Help file On-Line shapes for rules on typing the shape name.
WARNING 41087 Invalid shape names for members or columns were found. These were changed to: RE1X1. Please see warning log for more details. There are shape names that not allowed to be used in RISA because they conflict with default names or do not follow the naming convention rules. Try to rename the shape using a different name or review the Help file On-Line shapes for rules on typing the shape name.
WARNING 41088 More than MAX_NO_MTO in MTO Report! Report was Truncated. The Material Takeoff report is limited to a certain size, and the takeoff in your model exceeds that size. Contact RISA to request that the maximum size of Material Takeoff reports be increased.
WARNING 41089 British HR Steel : High Shear Bending Capacity Failed, Section 4.2.5.3 The member failed. See the code reference from the warning.
WARNING 41095 Round Shapes for Beams are not supported. No design is provided for round concrete beams Either change the member type so that it is a column, or change the cross section to be rectangular.
WARNING 41096 Required reinforcement exceeds maximum reinforcement ratios and/or reinforcement spacing restrictions. No Code Check Possible. The reinforcement required to meet strength demand violates minimum bar spacing or maximum reinforcement ratios for the beam. Review the Design Rules assigned to this element and make sure they are appropriate for the level of loading. Alternatively, adjust the size or thickness of the element.
WARNING 41099 Rebar(s) falls outside the cross section. They are ignored in Capacity Calculation. The user defined bar layout assigned to this member results in bars that do not fall within the cross section. Edit the bar layout defined to this member.
WARNING 41100 The rebar provided is more than Maximum Allowed by Code for a singly reinforced beam. Acceptable steel ratios are controlled by the ACI 318 and other code provisions. The codes limit the max steel that can be used for member reinforcement. Adjust concrete reinforcement design rules to adhere to code maximum reinforcement provisions.
WARNING 41102 Factored torsional moment Tu exceeds the threshold torsion per ACI 318-14/19 22.7.4.1 Beams and columns ignore torsion with respect to design of shear reinforcement. When using the ACI 318-02 or newer, RISA will check the member torsion value against the Threshold Torsion code provided value. (ACI 318-11 11.5.1, ACI 318-08 11.5.1, ACI 318-05 11.6.1, ACI 318-02 11.6.1, ACI 318-99 11.6.1) The shear reinforcement will have to be designed by the engineer for torsion.
WARNING 41107 Custom rebar layout does not meet min steel (As,min) per Model Settings. The member custom reinforcement ratio does not meet the minimum steel reinforcement set in the Model Settings. Either increase the member's custom reinforcement area or decrease the member's gross concrete area. The min steel area in the Model Settings can also be adjusted with regards to code provisions for minimum steel requirements.
WARNING 41108 Custom rebar layout does not meet min steel (As,min) per ACI 318 requirements. The member custom reinforcement ratio does not meet the minimum steel reinforcement per code provisions. Either increase the member's custom reinforcement area or decrease the member's gross concrete area.
WARNING 41110 Unable to provide min steel (As,min) per ACI -318 requirements. The member's reinforcement design does not meet the code requirements for minimum steel reinforcement ratio. Increase the member's reinforcement design rule to meet code provisions for minimum steel reinforcement ratio.
WARNING 41120 The shear tie spacing does not meet the code Minimum Requirement. Member shear tie spacing is less than the minimum spacing allowed by the applicable code provisions.. Adjust the member shear tie spacing to meet code minimum requirements.
WARNING 41121 No investigation! Circular layout is applied to a rectangular section or vice versa. No design done. Either a custom circular reinforcement layout has been applied to a rectangular member or a custom rectangular reinforcement layout has been applied to a circular member. Define a custom rebar layout applicable to the member shape type.
WARNING 41122 Compression Pu exceeds 0.75*Pc (Euler buckling). The program will not give design results for columns which have more than 75% of Euler Buckling load as the intention of ACI 318-14/19 Eqn 6.6.4.5.2 (ACI 318-11 Eqn 10-12). Increase the column member size which in turn will increase the Euler Buckling capacity.
WARNING 41123 Span qualifies as a 'Deep Section'. No Design for this Span. Span qualifies as 'deep beam' per ACI 318-14/19 Section 9.9.1.1(a) (ACI 318-11 Section 10.7) where the member clear span is equal to or less than four times the total member depth (h). RISA does not design for deep beams. The engineer is responsible for member design.
WARNING 41125 Shear bars are not provided along entire column length. Generally, concrete columns will have shear bars provided along the entire length of the column because of lateral confinement requirements. This member has its shear bars assigned using a custom rebar layout (it's not being optimized) and there is a region where no shear bars were specified. Look at the shear rebar layout being used for this column and make sure there are no regions without shear bars. If the concrete design code being used permits columns to have regions without shear reinforcement, this warning can be ignored.
WARNING 41126 Data missing in XML file Record Ignored. Data is missing in the wood database XML file referred to in the model. Edit or enter useable data in the XML wood database at the given row and column.
WARNING 41129 Invalid design rule offset is detected in a section. Changed to the first design rule in the list. The program has detected corrupt information for the specified element's design rule. The design rule was changed to the first listed design rule. Recheck entries for the specified element's design rule for any inconsistencies.
WARNING 41138 No Design of Slabs with Thickness < XX. The slab thickness is less than the indicated thickness. No design is done. Increase the slab thickness or the slab design needs to be done with hand calculations.
WARNING 41139 No Design of Design Cuts with Width < XX The design strip width is less than the indicated width. No design is done. Increase the design strip width to receive reinforcement design.
WARNING 41140 Top/bot cover value too large. 40% of thickness used instead. The program's concrete solver was not designed to accommodate very large cover values relative the thickness. Therefore a maximum cover value of 40% of the element's thickness was used instead of the cover value specified in the rebar design rules. Modify the element thickness or the cover dimension so that the cover dimension is no more than 40% of the thickness.
WARNING 41160 Unstable Joint with load applied to it has been fixed. Load will not be applied to the model. The given joint is unstable for translation and/or rotation. The load applied at the joint will not be applied to the model at solution time. Address the joint's instability by restraining the translation and/or rotation at that location.
WARNING 41166

Poission's ratio of a plate must be >= 0. and <= .5 .

The ratio of the plate's lateral strain to axial strain does not fall within the allowable range. Adjust the properties and/or the applied loads on the plate to meet the allowable Poisson's ratio range.
WARNING 41170 Max Limit Exceeded! - Records not read. When opening and reading a model file, one more Program Limits were exceeded in the data sections shown in the Warning Log. This situation can occur if a model created in the 64 bit version of a program is opened in the 32 bit version of the same program. In certain rare cases, we may have reduced the allowable number of some data elements in later program versions. Alternately, the file may have gotten corruped. You can send the file to RISA Techonologies so we can see why the program limits are being exceeded, and in some cases we can fix the model file.
WARNING 41174 IS-800 Table 3.1 (i) : Max Slenderness Ratio exceeds 180 for Compression Member XX IS-800 Table 3.1 (i) limits members carrying compressive loads resulting from DL and imposed loads to a max slenderness ratio (KL/r) of 180. Increase the member size, address the member's unbraced length, or decrease the applied compressive load on the member.
WARNING 41175 IS-800 Table 3.1 (ii) : Max Slenderness Ratio exceeds 180 for Tension Member XX IS-800 Table 3.1 (ii) limits tension members in which a reversal of direct stress occurs due to loads other than wind or seismic forces to a max slenderness ratio (KL/r) of 180. Increase the member size, address the member's unbraced length, or decrease the applied tension load other than wind or seismic on the member.
WARNING 41176 IS-800 Table 3.1 (iii) : Max Slenderness Ratio exceeds 250 for Compression Member XX IS-800 Table 3.1 (iii) limits members subjected to compression forces resulting only from combination with wind/earthquake forces to a max slenderness ratio (KL/r) of 250. Increase the member size, address the member's unbraced length, or decrease the applied wind or seismic compression load on the member.
WARNING 41177 IS-800 Table 3.1 (iv) : Max Slenderness Ratio exceeds 300 for Compression Flange of Member XX IS-800 Table 3.1 (iv) limits the compression flange of beam members against lateral torsional buckling to a max slenderness ratio (KL/r) of 300. Increase the member size, address the member's unbraced length, or decrease the applied compressive load on member's flange.
WARNING 41178

IS-800 Table 3.1 (v) : Max Slenderness Ratio exceeds 350 for Bracing Member XX

IS-800 Table 3.1 (v) limits members acting as ties in a roof truss or bracing system not considered effective when subject to reversal of stress into compression resulting from wind or earthquake forces to a max slenderness ratio (KL/r) of 350. Increase the member size, address the member's unbraced length, or decrease the applied wind or seismic compression load on the member.
WARNING 41179 IS-800 Table 3.1 (vi) : Max Slenderness Ratio exceeds 400 for Tension Member XX IS-800 Table 3.1 (vi) limits members always under tension, other than pre-tensioned members, to a max slenderness ratio (KL/r) or 400. Increase the member size, address the member's unbraced length, or decrease the applied tension load on the member.
WARNING 41196 Sum of X/Y/Z reaction is not equal to the sum of the loads (LC XX)! Check for any small rigid links or fixed boundary conditions. The reactions in the given Joint Reactions spreadsheet do not equal the applied loads. Address one of the following possibilities for this error message: change any "Fixed" boundary conditions to "Reaction"; address instabilities in your model where the program is creating a LOCKED joint; check for areas of high rigidity which are simulating boundary conditions. See Sum of Reactions for more information.
WARNING 41219 Mesher Error Something has gone wrong in the RISA mesher. This particular warning contains troubleshooting code for the RISA developers. Contact RISA Support. Send your model, and the exact warning you get.
WARNING 41251 Shape changed from XX to ZZ. Design List changed from XX to ZZ. The member shape or (re)design list previously saved to the model has been changed in the input file. Accept changes or redefine the previously used shape and (re)design list in the model.
WARNING 41253 The wood schedule used in this model is not available on this computer. Please obtain a copy of the database from the author of this model. The wood schedule saved to this model is not available on this computer. A default wood schedule was used instead. Obtain the database from the author of this model in order to obtain the wood schedule item previously saved to the model.
WARNING 41257 No wood schedule is found in the input file. Use the default wood schedule instead. No wood schedule was defined in the input file. A default wood schedule was used instead. Redefine the wood schedule in the input file.
WARNING 41258 Corrupted wood schedule with 0 wood mark is detected in the input file. Use the default wood schedule. Something in the wood schedules saved with this model is corrupted. Check the wood schedules in the Wall Design Rules spreadsheet to be sure that the correct wood schedules are referenced.
WARNING 41260 Corrupted wood diaphragm schedule with 0 diaphragm is detected in the input file. The default wood diaphragm schedule is used. Something in the wood schedules saved with this model is corrupted. Check the wood schedules in the Diaphragms spreadsheet to be sure that the correct wood schedules are referenced.
WARNING 41261 This model contains masonry and/or wood walls with custom regions and/or headers AND optimization is currently turned off. See the help file for more information. The masonry or wood regions have been assigned explicit custom properties, so they are not being optimized per the design rule. Alternatively, optimization is turned off. Either way, the walls are being analyzed as-is, as opposed to getting optimized. If you would like wall optimization design, reset the walls to be designed per design rule, or turn on optimization.
WARNING 41262 Wood Grade of XX could not be identified. Changed to ZZ. The wood grade previously saved to this model could not be identified. The given wood grade was used instead. Redefine the given wood grade in the model.
WARNING 41263 Wood Species of XX could not be identified. Changed to ZZ. The wood species previously saved to this model could not be identified. The given wood species was used instead. Redefine the given wood species in the model.
WARNING 41264 Species XX in ZZ could not be identified, check wood materials! The wood species material defined in the input file could not be identified. Define the wood species material from the available options in the Materials spreadsheet.
WARNING 41265 No design will be done for wood walls that are using Design Rule with XX panel. The wood walls assigned to the referenced design rule could not be designed. Check your design rule and adjust the design parameters to allow for a passing design.
WARNING 41266 Wall Design Rule XX: Changed to ZZ. The given wall design rule previously saved to the model has been changed in the input file. Accept changes or redefine the previously used wall design rule in the model.
WARNING 41267 No rebar layout found for member XX, Optimize assigned. The rebar layout defined for the given member was not found. The "Optimize" option will be used instead. If a custom rebar layout is preferred over optimization, reassign a custom layout to the given member from the available custom layout options currently in the model.
WARNING 41271 User defined XX changed from YY to ZZ Contact RISA for more information. Contact RISA for more information.
WARNING 41272 User defined left effective width exceeds geometry for beam The composite / Tee beam effective width entered by the user violates the maximum allowed effective width based on beam geometry or spacing. Review the effective width used for this beam
WARNING 41273 User defined left effective width exceeds span/8 for beam The composite / Tee beam effective width entered by the user violates the maximum allowed effective width based on 1/8th the beam span. Review the effective width used for this beam
WARNING 41274 User defined right effective width exceeds geometry for beam The composite / Tee beam effective width entered by the user violates the maximum allowed effective width based on beam geometry or spacing. Review the effective width used for this beam
WARNING 41275 User defined right effective width exceeds span/8 for beam The composite / Tee beam effective width entered by the user violates the maximum allowed effective width based on 1/8th the beam span. Review the effective width used for this beam
WARNING 41276 Wall design rule offset was invalid and is defaulted to the the first wall design rule. The wall panel design rule assigned to the given wall panel is invalid. The first wall panel design rule was used instead. Assign a wall panel design rule currently available in the model to the given wall panel.
WARNING 41277 Wall material offset was invalid and is defaulted to the the first material. The wall panel material assigned to the given wall panel is invalid. The first material available was used instead. Assign a wall panel material currently available in the model to the given wall panel.
WARNING 41278 The default wood panel group XML files are missing and no other alternatives were found. Using dummy values. The default wood properties are not found in the XML files. Dummy values were used instead. Either add the wood properties to an XML file or set the currently available XML files as the default.
WARNING 41280 All panels in selected wood panel group are ineffective based on thickness criteria in Design Rule. The program was not able to select a wall panel in the wood panel group due to the thickness constraints defined in the Design Rule. Increase the range for the max and min thickness values in the Wall Panel Design Rule.
WARNING 41281 All panels in selected wood panel group are ineffective based on nail spacing criteria in Design Rule. The program was not able to select a wall panel in the wood panel group due to the nail spacing constraints defined in the Design Rule. Increase the range for the max and min nail spacing values in the Wall Panel Design Rule.
WARNING 41282 All panels in selected wood panel group are ineffective based on \Double Sided\" criteria in Design Rule." The program was not able to select a wall panel in the wood panel group due to the Double Sided criteria defined in the Design Rule. Select another option for the Double Sided criteria in the Wall Panel Design Rule.
WARNING 41283 Selected panel with _W is invalid in Design Rule." Very old wood databases contained wood wall panels that had incorrect values, and which had "_W" in their name. These panels are ignored to prevent errors. Use a different panel for the wood wall.
WARNING 41288 Column has a span less than 5 analysis sections. Cannot Perform Concrete Design. The concrete column is too short for an accurate design. Less than 5 cuts could be made in its span, so flexural theory would not be applicable.

In order to perform concrete rebar design, the program needs to have a good representation for what sort of moment and shear diagrams exists in the member. When there are less than 5 internal sections in a beam or span, the program will warn you that it did not have enough information to perform an adequate concrete design. Increasing the number of internal sections on the Model Settings Dialog may correct this problem.

Since, the program wants to perform shear design at a distance "d" from the face of support, it may not be possible to get rebar design for members with a large depth and a relatively short span. Keep in mind that this will only affect rebar design. Deflection and force results are unaffected.

WARNING 41297 Wall Panel is failing a reinforcement requirement. See detail report for more information. The wall panel specified is not meeting reinforcement requirements. Access the wall detail report for further information. Adjust the wall panel design rule to meet reinforcement requirements.
WARNING 41298 Wall region is using an uncommon block size. No self weight defined for this wall. Apply weight manually. If you choose an odd block material and thickness then the NCMA tables do not tabulate the self-weight for these cases. Either use a more common block or manually calculate the self-weight of wall and apply it as a load in DL category.
WARNING 41302 One or more walls have a thickness <= 0. Please correct this to export the walls to RISA-3D." Walls must have a thickness greater than zero. Assign a thickness greater than zero in the Modify Walls dialog box.
WARNING 41308 Duplicate shape name was found in database. Changed from XX to YY Two different shapes may not have the same name. One of the shapes' names was altered so that they do not have the same name. Rename the shapes as appropriate, or just use the updated naming that was automatically applied.
WARNING 41332 Composite design not done : Beam has negative moment along its span. Negative bending moment on the beam places the concrete slab in tension. RISA cannot perform a composite design when the slab is in tension. Change the beam to be non-composite.
WARNING 41362 Steel code check not calculated. The program was not able to perform a steel code check for this member. Member is not defined with a database shape or a steel code is not specified on the Model Settings or no units were specified. For LRFD this message is displayed if the steel yield stress is less than 10 ksi. See Detail Report for more information.
WARNING 41363 Web is slender per Table B5.1, handle as a plate girder. Web is slender per Table B5.1, handle as a plate girder. The ratio h/tw exceeds the limiting criteris listed in Table B5.1. This means Chapter G (plate girders) governs and must be considered by engineer.
WARNING 41364 Compressive stress fa exceeds F'e (Euler buckling). The stress in the member exceeds the Euler Buckling stress. Therefore this member would buckle and fail, so no code check is possible for it. Decrease the load on the member, or decrease the unbraced lengths on the member, or choose a member with larger radius of gyration.
WARNING 41365 Tube depth>6*width (Sec F3-1). Width=bf-3*tw , Sec B5-1. Tube depth>6*width (Sec F3-1)where width=bf-3*tw , Sec B5-1. A tube is failing to meet the depth/width requirements laid out in Section F3-1 of the ASD code. The depth of the tube is the full nominal depth, which the width is taken as the full width minus 3 times the thickness. Section B5-1 specifies this calculation for the width when the fillet radius is not known.
WARNING 41366 Tee or Channel fails on Table A-B5.1 (Appendix B). Tee or Channel fails on Table A-B5.1 (Appendix B). This message appears for ASD code checking when Appendix B calculations are being done for a Tee or Channel shape and the shape fails to meet the requirements of Table A-B5.1, Limiting Proportions for Channels and Tees.
WARNING 41368 Pipe diameter/thickness ratio > 13,000/Fy (App. B). Pipe diameter/thickness ratio > 13,000/Fy (Appendix B). This message appears when Appendix B calculations are being done for a pipe shape and the diameter/thickness ratio exceeds the limit of 13000/Fy specified in Section B5-b for ASD, Section B5-3b for LRFD.
WARNING 41370 Can't do single angle code check, eccentricity unknown. Can't do single angle code check, eccentricity unknown. Code check not performed for single angle members.
WARNING 41371 Slender tube, currently don't do LRFD App. B5-3b calcs. Slender tubes are not supported for this design code. Choose a tube which is not slender, or choose a different design code which supports them.
WARNING 41372 Taper Flange area is not constant per App. A-F7-1(b). Code check provisions for tapered members require a constant flange area. If a code check is desired then the member properties will have to be changed so that the flanges does not taper.
WARNING 41373 Taper rate exceeds gamma limit per App. A-F7-1(c). Code check provisions for tapered members limits the taper rate to approximately 15 degrees. If a code check is desired then the member properties will have to be changed to a smaller degree of taper.
WARNING 41374 Flanges not equal, currently don't do LRFD App.F1 calcs. Older AISC codes (LRFD2nd?) does not allow code checks for tapered members with unequal flanges Either change the properties of the member, or switch to a newer code (AISC 13th / 14th/ 15th) which does not have the same restrictions
WARNING 41375 Taper Comp. flange < Tension flange, per App. A-F7-1(b). Older AISC codes (ASD 9th?) does not allow code checks for tapered if the compression flange is smaller than the tension flange. Either change the properties of the member, or switch to a newer code (AISC 13th / 14th/ 15th) which does not have the same restrictions
WARNING 41376 Tension member with L/r ratio > 300 (CAN Sect. 10). Tension member with L/r ratio > 300 (CAN Sect. 10). The maximum L/r ratio for this tension member exceeds the limit shown in Section 10.2.2 of the CAN/CSA S16.1-94 code.
WARNING 41377 KL/r > 200 for compression member (CAN Sect. 10). KL/r > 200 for compression member (CAN Sect. 10). The maximum L/r ratio for this compression member exceeds the limit shown in Section 10.2.1 of the CAN/CSA S16.1-94 code. You may override this check in the Preferences on the Tools menu.
WARNING 41378 Can't do code check for slender compression member. Can't do unity check for slender compression member. Compression strengths are not calculated for shapes that contain elements where the width to thickness ratios are classified as “slender”.
WARNING 41379 Can't do code check for slender web flexural member. Can't do unity check for member with slender web. Flexural strengths are not calculated for shapes which have a web depth to thickness ratio classified as “slender”.
WARNING 41380 Currently can't do code checks for slender flange member. Currently can't do code checks for slender flange member. Flexural strengths are not calculated for shapes which have a flange width to thickness ratio classified as “slender”.
WARNING 41381 Can't do code check for single angles in compression. Can't do code check for single angles in compression. Compression strengths are not calculated for single angle members.
WARNING 41382 Can't do code check for Tube with slender web. Can't do code check for tube with slender web. Flexural strengths are not calculated for shapes which have a web depth to thickness ratio classified as “slender”.
WARNING 41383 Can't do code check for Non Compact/Slender Channel. Can't do code check for non-compact/slender channel. The AISC 9th Edition (ASD) specification does not specifically address the allowable stress for weak axis bending of channels. The program uses the most similar formula for the weak axis bending of wide flanges (0.75*Fy). For a complete and thorough treatment of channel code checks, refer to the LRFD specification.
WARNING 41384 Pipe diameter/thickness ratio > 0.45*E/Fy. The currently selected design code does not support pipes with cross sections this slender. Choose a pipe with a less slender cross section, or choose a design code which supports this shape.
WARNING 41385 KL/r > 200 for compression member. The AISC code recommends, but does not require that the slenderness for compression members not exceed 200. Choose a member with a larger radius of gyration, or set the unbraced length to a smaller value. If you would like to override this limitation (and thereby override the AISC recommendation) go to the Tools Menu, and under Preferences check the "Allow KL/r > 200" box.
WARNING 41386 L/r > 300 for tension member. The AISC code recommends, but does not require that the slenderness for tension members not exceed 300. This warning is flagged when the tension force exceeds the threshold of 1% of Ft where Ft is the material yield stress multiplied by the area of the member. Choose a member with a larger radius of gyration, or set the unbraced length to a smaller value. If you would like to override this limitation (and thereby override the AISC recommendation) go to the Tools Menu, and under Preferences check the "Allow L/r > 300" box.
WARNING 41387 Tapered flanges are not allowed. RISAFloor does not support the design of tapered members; therefore no design could be done. Use a non-tapered member, or use RISA-3D to design this member.
WARNING 41388 Chapter H - Iyc/Iy provision not satisfied. The Iyc/Iy ratio limits from AISC 360 section H1.1 were not met. Check your member cross-sectional properties. The chapter H equations may not be appropriate.
WARNING 41389 This load combination was not selected for steel design. Steel member design cannot be done for this Load Combination because it was not selected for steel design. Check the appropriate material check-box on the Design tab of your Load Combinations spreadsheet.
WARNING 41390 Rho >= 1.0 (Eqn 6.29), No code check calculated. Contact RISA for more information. Contact RISA for more information.
WARNING 41391 Rho >= 1.0 (Eqn 5.22), No code check calculated. Contact RISA for more information. Contact RISA for more information.
WARNING 41392 The web tapered angle is larger than 15 degree. RISAFloor does not support the design of tapered members; therefore no design could be done. Use a non-tapered member, or use RISA-3D to design this member.
WARNING 41393 Flange slenderness requirement is not satisfied. Contact RISA for more information. Contact RISA for more information.
WARNING 41394 The web slenderness requirement is not satisfied. Contact RISA for more information. Contact RISA for more information.
WARNING 41395 bf < h/9 over the entire unbraced length. Contact RISA for more information. Contact RISA for more information.
WARNING 41396 The web thickness is greater than the flange thickness. Contact RISA for more information. Contact RISA for more information.
WARNING 41397 Tapered member is not designed. RISAFloor does not support the design of tapered members, therefore no design could be done. Use a non-tapered member, or use RISA-3D to design this member.
WARNING 41398 No code check for noncompact pipe members. RISA cannot calculate the capacity of noncompact pipe members for the chosen design code. Use a compact pipe, or choose a design code where noncompact pipes are supported.
WARNING 41399 Can't do code check for both web and flanges as Class 4. RISA cannot calculate the capacity of members with very slender flanges and webs for the chosen design code. Use a shape that does not have both webs and flanges being very slender, or use a design code that supports this.
WARNING 41400 No code check. Shear buckling possible. Contact RISA for more information. Contact RISA for more information.
WARNING 41401 AISI code check not calculated. An AISI member capacity could not be calculated. See the member's Detail Report for more information.
WARNING 41402 Can't do code check, stiffener D/w > 0.8 (Sect. B4.2). The AISI code does not address stiffeners that are much wider than the flange. Therefore a capacity could not be calculated. Use a section where D/w does not exceed 0.8, or peform a hand calc to determine the capacity which AISI does not address.
WARNING 41403 Stiffener angle gamma is < 40 or > 140 (Sect. B4.2). The AISI code does not address stiffener angles outside of the 40 - 140 degree range. Therefore a capacity could not be calculated. Use a section where the stiffener angle falls within the acceptable range, or peform a hand calc to determine the capacity which AISI does not address.
WARNING 41404 Can't do code check, flange w/t > limit (Sect. B1.1) The AISC code Chapter B limits the width to thickness ratio. Choose a section that is within the limits.
WARNING 41405 Can't do code check, web h/t > 200 (Sect. B1.2) The AISC code Chapter B limits the height to thickness ratio. Choose a section that is within the limits.
WARNING 41406 Euler Buckling Exceeded (Sect C5.2) The member stress exceeds the code Euler Buckling limit meaning the member will buckle and no code check can be done. You need to reduce your effective length by reducing the actual length between supports or using a larger shape.
WARNING 41408 Wood code check not calculated. The program was not able to perform a code for your wood member. See the member detail report for more information. It could mean that you have not selected a Design Code in Model Settings, or you have not included any load combinations for this material type in your solution. Check the Design tab of the Load Combinations spreadsheet.
WARNING 41409 RB value is greater than 50. Section 3.3.3.7 of the NDS 2012, 2005, 2001, and 1991/1997 codes limits the slenderness ratio RB to a maximum of 50. Similarly, clause 6.5.6.4.3 of the CSA O86-09 limits CB to a maximum of 50. You will need to reduce the effective span length, increase the thickness of the shape, or reduce the depth of the shape.
WARNING 41410 le/d is greater than 50. Section 3.7.1.4 of the NDS 2012, 2005, 2001, and 1991/1997 codes limits the column slenderness ratio of Le1/b or Le2/d to a maximum of 50. You need to reduce your effective length by reducing the actual length between supports or changing the effective length factor “K”. You can also use a thicker shape.
WARNING 41411 fc is greater than FcE1. Section 3.9.2 of the NDS NDS 2012, 2005, 2001, and 1991/1997 codes limits the actual axial compressive stress to be less than the term FcE1. This term is approximately the Euler buckling stress for buckling about the strong axis of the member. (Buckling is in the plane of bending) You need to reduce your effective length by reducing the actual length between supports or using a thicker shape.
WARNING 41412 fc is greater than FcE2. Section 3.9.2 of the NDS 2012, 2005, 2001, and 1991/1997 codes limits the actual axial compressive stress to be less than the term FcE2. This term is approximately the Euler buckling stress for buckling about the weak axis of the member. (Buckling is in the plane of bending) You need to reduce your effective length by reducing the actual length between supports or using a thicker shape.
WARNING 41413 fb1 is greater than FbE. Section 3.9.2 of the NDS 2012, 2005, 2001, and 1991/1997 codes limits the actual strong axis bending compressive stress to be less than the term FbE. This term is approximately the lateral buckling stress. You need to reduce your effective length by reducing the actual length between supports or using a thicker shape.
WARNING 41414 Structural Composite Lumber only checked for NDS 2001. The chosen design code is not supported for Structural Composite Lumber. NDS 2001 or newer codes must be used for SCL design. CSA O86-09 code is not supported for SCL design at this time. Choose a newer design code that supports the design of structural composite lumber, or use dimension lumber.
WARNING 41498 The solution file was created with an older version of RISA. Some information may not be present. The solution file saved with the model was saved with an old format that may be missing some data which the new version would provide. Re-solve the model in the new version.
WARNING 41499 Segmented Wood Wall Shear Panel Results are based on saved results from version XX. The solution file saved with the model was saved with an old format that may be missing some data which the new version would provide. Re-solve the model in the new version.
WARNING 41500 Internal Results Corrupted Solution results may be corrupted. Please contact RISA. Contact RISA.
WARNING 41505 Shear Fy for Material: Exceeds the Limits of ACI 318-14/19 Section 20.2.2.4 The shear Fy for the material used exceeds the limits given in ACI 318-14/19 Section 20.2.2.4 (ACI 318-11 Section 11.4.2). Decrease the shear Fy value for the applicable material to meet these requirements.
WARNING 41517 Unable to establish span information for member The program is unable to determine the correct framing setup for concrete members in your structure.

The program assumes that each beam will be supported vertically by two columns, plates or boundary conditions. It also assumes that each column will be supported laterally by two beams, plates, or boundary conditions.

The program uses this information to determine "span" information for beams and columns. This span information is then used for concrete rebar design.

If you would like to suppress these warnings in the future, just go to the Concrete tab of Model Settings Dialog and uncheck the Bad Framing Warnings box.

WARNING 41521 Distance between the points is too close. See Slabs-Automatic Meshing. The distance between the given points is too close for the slab plate mesh to be generated. Increase the distance between the given points or decrease the slab mesh area in the Model Settings.
WARNING 41522 Distance between the point XX and slab boundary is too close. See Slabs-Automatic Meshing. The distance between the given point and the slab edge boundary is too close for the slab plate mesh to be generated. Increase the distance between the given point and the slab edge boundary or decrease the slab mesh area in the Model Settings.
WARNING 41526 Section set: Shape Name changed from XX to ZZ. The shape name denoted in the given Section Set has been changed in the database. Accept changes or change the shape name in the Section Properties dialog box.
WARNING 41527 Rebar falls outside of the lintel in the Wall Panel. This lintel is not designed. Contact RISA for more information. Contact RISA for more information.
WARNING 41528 Wall Panel is not vertical. Wall panels must be in the vertical plane rather than in the horizontal plane or any other orientation. Draw the wall panel in the vertical plane otherwise use plate elements for any other orientation.
WARNING 41529 Wall Panel is not rectangular. Wall panels must be drawn as a rectangle. Draw the wall panel as a rectangular element otherwise use plate elements for any other shape type.
WARNING 41530 Lintel of Wall Panel %s is not horizontal. Contact RISA for more information. Contact RISA for more information.
WARNING 41531 Wall Panel: One of the end shear panels does not meet the aspect ratio limitations. Design Not Done The height-to-length ratio of an end region in this wall violates the maximum ratio allowed ratio per the code. For Perforated and force Transfer around Openings design methods no design can be done for the wall. Change the wall design method to Segmented to get design of the conforming regions. Alternatively, adjust the given wall panel's geometry so that all of the regions meet aspect ratio limitations of the code.
WARNING 41532 Wall Panel : No openings in the shear wall. Segmented design method used. Perforated or Force Transfer design method cannot be used for a wall without openings. Specify openings in the wall or use the Segmented design method for walls without openings.
WARNING 41533 Wall Panel: Multiple regions have been drawn per shear panel. Design not done. Contact RISA for more information. Contact RISA for more information.
WARNING 41534 Wall Panel: Holddowns and straps do not align in the wallpanel stack. The holddowns in a wall panel stack do not align vertically. This is only a warning and can be ignored in some cases. Holddowns can be influenced by perpendicular walls framing into the given wall or other framing scenarios. Check that the wall panels in the wall panel stack align.
WARNING 41535 Wall Panel: Stud spacing exceeds 24 inches. Stud spacing greater than 24 inches is not allowed per NDS SDPWS Section 4.3.7.1.5 Reduce the stud spacing to no more than 24" o.c.
WARNING 41536 Wall Panel: Straps do not align with chords on the wall below. The straps on the wall above, which carry a concentrated uplift force due to wall overturning, are landing in the middle of the wall below. There is no continuous chord member below to carry this uplift down to the foundation. The load is being spread out to the studs instead. Rearrange the walls so that a wall or segment edge lands right where the strap is. The program places a Chord member at the edges of walls and segments. Otherwise, account for this discontinuous load path through manual calculations and detailing.
WARNING 41537 Wall Panel : Perforated walls cannot be sloped. Design Not Done. The perforated design method is not allowed for sloped walls per NDS SDPWS Section 4.3.5.3.6 Use a different design methodology such as Segmented or Force Transfer around Openings. This can be set in the Wall Panels spreadsheet, Advanced tab.
WARNING 41538 Wall Panel: Perforated walls must be less than 20ft tall. Design Not Done. The perforated design method is not allowed for sloped walls per NDS SDPWS Section 4.3.5.3.7 Use a different design methodology such as Segmented or Force Transfer around Openings. This can be set in the Wall Panels spreadsheet, Advanced tab. Otherwise, split the wall into two shorter walls stacked atop each other.
WARNING 41539 Wall Panel : Selected sheathing shear capacity exceeds the limits of NDS 2005 SDPWS section 4.3.5.3. The NDS SDPWS places an upper limit on the shear capacity for wood sheathing. Use a sheathing that does not exceed the upper limits prescribed by the NDS.
WARNING 41540 Wall Panel: Selected sheathing shear capacity exceeds the limits of NDS 2008 SDPWS section 4.3.5.3. The NDS SDPWS places an upper limit on the shear capacity for wood sheathing. Use a sheathing that does not exceed the upper limits prescribed by the NDS.
WARNING 41541 Wall Panel: Door opening is not allowed for the Force Transfer Around Opening method. Design Not Done. RISA does not support door openings for the FTAO method. Use a different design methodology such as Segmented or Perforated. This can be set in the Wall Panels spreadsheet, Advanced tab.
WARNING 41542 Wall Panel: The height to width ratio of the overall wall is greater than 3.5. Design Not Done. The NDS SDPWS places an upper limit on wall aspect ratios per Section 4.3.4 This wall must be ignored for shear resistance. If reconfiguring the wall to meet the required aspect ratio is not possible then remove the wall from the model.
WARNING 41543 Wall Panel : Length of the shear panel should be more than 2 ft. Design Not Done. Shear panels less than 2 feet in length are forbidden by the NDS SDPWS per Section 4.3.5.2.1 This shear panel must be ignored for shear resistance. If reconfiguring the wall to meet the required aspect ratio is not possible then remove the wall from the model.
WARNING 41544 Wall Panel : No adequate hold-down found in database. None of the hold downs in the database specified in the Wall Design Rules spreadsheet, Wood Wall Fasteners tab were adequate for the uplift loads. Reduce the uplift forces on the wall or specify a different hold-down database that has adequate capacities for the hold-down forces.
WARNING 41545 Wall Panel: Hold-down failed. The hold-down specified in the Wall Design Rules spreadsheet, Wood Wall Fasteners tab was inadequate for the uplift loads. Reduce the uplift forces on the wall or specify a different hold-down that has adequate capacities for the hold-down forces.
WARNING 41546 Value of rT = 0. Reset to 41000. The value of rT is set to zero in the shape database, but this value cannot be zero for code check calcuations so a dummy value was used instead. This value is incorrect for the member, so the capacity calculations are incorrect. Set the rT value for this shape to be a value larger than zero in the Shape Database.
WARNING 41550 No species/grade combination in database for XX. The wood database does not have allowable stress values for the specified member size with the specified species/grade Choose a lumber size which the code tables have an allowable stress for, or choose a different species/grade which the code tables have values for this lumber size. Otherwise check this member by hand, with allowable stresses not taken from the code tables.
WARNING 41551 Member XX : No XX in. thickness/wide values in database for XX. The wood database does not have allowable stress values for the specified member size with the specified species/grade Choose a lumber size which the code tables have an allowable stress for, or choose a different species/grade which the code tables have values for this lumber size. Otherwise check this member by hand, with allowable stresses not taken from the code tables.
WARNING 41557 The wood hold down series used in this model is not available on this computer. Please obtain a copy of the database from the author of this model. The computer where this model was created had a hold-down database different from the hold-down database on the computer where you have opened it. Hold-down design may be different when solved on this comptuer. Use the hold-down database values on the computer where you have opened the model, or obtain the hold-down database from the computer where the model was created.
WARNING 41559 There was an error obtaining wood hold down database info. You may not have any database files available. Default wood hold down series used instead. The hold-down databases on this computer may be corrupted. Default values are being used, but may be incorrect. Look at the hold-down databases in the RISA\Wood Schedules folder. Fix the problems with these files.
WARNING 41583 Wall Panel XX: Masonry cover value updated because input value does not fall within the masonry block core. If you define a cover where the bar then hits the faceshell of the masonry block then this message is given. Adjust the cover in the Wall Design Rules so that the reinforcement is completely within the masonry core.
WARNING 41586 LCXX: Service Flag setting is different for the Mass LC and this LC. The different Stiffness Matrices being used will give inconsistent results. For a dynamic or a time history solution, it is possible to have your mass matrix and solution matrix based on different service flags. This will cause an inherent consistency in the results. The level of cracking assumed (for concrete members or walls) during the dynamic solution (mode shapes / natural frequencies) is inconsistent with the level of cracking assumed in the solved load combination, which depends on the dynamic solution results.
WARNING 41589 Wall Panel XX: Region(s) XX do not satisfy the h/w ratio. Design skipped for that region. The NDS wood code requires certain h/w ratio limits be met to allow a region in a wall segment to be used as a shear wall.  If these ratios are not met then this region is ignored for shear wall purposes. The shear stiffness (not the axial) is removed from this wall region so that no shear force will accumulate in this region. This will then push all of the shear force to the qualifying wall segments.
WARNING 41590 Wall Panel XX: missing holddown/strap at (XX, XX, XX). Design Not Done. Segmented shear wall requires two holddowns/straps per shear panel. A strap or a hold-down is missing from the base of a full-height wall segment. Editing of a wood wall can, in some instances, cause a problem with the hold-downs/straps in a wall.  If this occurs you can double-click the wall in the wall panel editor and re-add the strap/hold-down where necessary.
WARNING 41603 The user defined Shear Modulus(G) for material XX is substantially higher than E/2(1+v) so it is being ignored; objects using this material will be treated as isotropic. A check is done on materials in the Materials spreadsheet to determine whether the input E and G values are matching. If G is much greater than mechanics of materials would suggest, the program will ignore the G and use the E/2(1+v) value. No action is required.
WARNING 41604 The user defined Shear Modulus(G) for material XX is below the isotropic value of E/2(1+v); plates/walls/diaphragms using this material will be treated as orthotropic. A check is done on materials in the Materials spreadsheet to determine whether the input E and G values are matching. If G is much smaller than the E/2(1+v) value this warning is generated and the input G is used. If this G was input on purpose then no action is required. If not then you may wish to update or delete your G value in the Material spreadsheet. The program will auto-calculate G if left blank.
WARNING 41607 Wall Panel XX has a height < 6 inch. Walls < 6 inches tall cause a problem with the mesher and thus the program does not allow it. If you have something that is < 6" tall then use plate elements rather than wall panels.

WARNING 41610

The selected sheathing panel for WPXX is not applicable for seismic applications. Check your load combinations. The CSA O86 sheathing tables define which panels are acceptable for seismic applications or not. This message will warn you if your wall is governed by a seismic load load combination but a non-applicable sheathing panel is selected. Select a different sheathing panel from the Wood Schedule database in the wall design rule.
WARNING 41611 Wall Panel XX: Perforated/FTAO design per the CSA O86 is not supported at this time. Segmented method used. The CSA O86 wood design manual only supports one wood wall design method: the Segmented Method. Therefore the program will automatically change to Segmented if you have selected another method. No action is required.
WARNING 41621 There are members defined as member type: "Beam" that are vertical (or nearly vertical). For proper deflection optimization, change member type to "Column". Members that are defined as "Beam" but oriented within +/- 10 degrees of vertical will be flagged. Only members that are defined as "Column" will act as a support for deflection criteria. Adjust member type to "Column".
WARNING 41633 The solution file is not from the same version as the program currently trying to read it. It was deleted. The solution file saved with the model was saved with a different version of RISA. Re-solve the model in the new version.
WARNING 41634 Insufficient memory to read the Solution Results file. It was deleted. There is not enough memory to read the solution file. Try solving the model using a Sparse Solver to reduce the amount of memory needed for the solution file.
WARNING 41635 There is a problem with the Solution Results file. It was deleted. There solution results file was unable to be read. Contact RISA.
WARNING 41636 An error occurred while reading Solution Results file. It was deleted. The solution results file was unable to be read. Contact RISA.
WARNING 41639 Single leg shear reinforcement is not supported and is present in the model file. All instances using this were changed to the minimum number of allowed legs for shear reinforcement, which is two. This model was previously created using single leg shear reinforcement which is not supported. The concrete reinforcement design rule was changed to have two legs for shear reinforcement. This is the minimum that is supported by the program.
WARNING 41652 The %s is not tension controlled in accordance with Table %s. The arrangement and amount of reinforcing steel is such that if the member fails it will fail in a brittle manner (Compression Controlled Section). This is not allowed, per ACI 318-19, Sections 7.3.3.1, 8.3.3.1, 9.3.3.1. The quantity and arrangement of rebar is such that the rebar is not yielding prior to a concrete failure. Change the dimensions of the cross section of the concrete or alter the rebar design rules such that the rebar yields first.
WARNING 41684 Wall Panel XX does not satisfy the length being at least 24 inches. Design skipped. This CFS/Wood geometric limitation must be satisfied. Revise the wall panel geometry to satisfy the limitations.
WARNING 41686 Unable to expand environment strings on user specified temp directory path. Problem with the user specified temp directory path. Check/revise your temp directory path.
WARNING 41687 Unable to expand environment strings on user specified temp directory path because result is too long. Problem with the user specified temp directory path. Check/revise your temp directory path. Try setting it to a local location.
WARNING 41688 User specified temp directory path cannot be used due to permission errors. Problem with the user specified temp directory path. Check/revise your temp directory path.
WARNING 41689 User specified temp directory path cannot be used because it does not exist. Problem with the user specified temp directory path. Check/revise your temp directory path.
WARNING 41690 User specified temp directory path cannot be used because it is not on a local disk. Problem with the user specified temp directory path. Check/revise your temp directory path. Make sure it is pointing to a local location.
WARNING 41691 User specified temp directory path cannot be used because due to an unexpected error. Problem with the user specified temp directory path. Check/revise your temp directory path.
WARNING 41692 Error reading user specified temp directory path. Problem with the user specified temp directory path. Check/revise your temp directory path.
WARNING 41693 The default CFS panel group XML files are missing, and no other alternatives were found. Using dummy values. The CFS panel group XML files are missing. Re-install the program to obtain the correct CFS panel group XML files.
WARNING 41707 Member XX: Shape changed to XX because XX was not found.    
WARNING 41717 No XX XML files found. Internal Default properties used. No XML file was found. The default XML will be utilized.
WARNING 41718 XX XML file was ignored. The filename is empty after trimming. File: XX; Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41719 XX XML file was ignored. The filename is too long. XX chars allowed. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41721 XX XML file ignored. Failed to load. XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41722 XX XML file ignored. Invalid format - missing Workbook tag. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41723 XX XML file ignored. Invalid format - missing Worksheet tag. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41724 XX XML file ignored. Invalid format - missing Table tag. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41725 XX XML file ignored. No rows found. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41726 XX XML file ignored. Invalid format - %s index out of order. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41728 XX XML file ignored. Row 1 missing or empty. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41729 Error occurred while loading XX XML files. Error: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41730 No loadable XX XML files found. Internal Default properties used. Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41731 XX XML file ignored. No loadable rows found. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41732 Worksheet in XX XML file ignored. No loadable rows found. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41733 XX XML file ignored. Row 2 missing or empty. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41734 Wallpanel XX: Two layers of reinforcement (each face) should be used for walls thicker than 210mm (14.1.8.3). More than a single layer of reinforcement is required when the wall is thicker than 210mm. Specify two layers of reinforcement (each face) in the Wall Design Rules.
WARNING 41736 XX XML file ignored. Invalid Format - XX index XX is not a valid number. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41737 XX XML file ignored. Invalid Format - XX index XX is out of range. Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41740 XX XML file ignored. Invalid format - Worksheet tag missing XX: Name attribute. File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41741 Worksheet in XX XML file ignored. Name is empty after trimming. Worksheet XX File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41742 XX XML file ignored. First worksheet name is empty after trimming. File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41743 XX XML file ignored. First worksheet name is too long. File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41744 Worksheet in XX XML file ignored. Name is too long. Worksheet XX File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41745 Worksheet in XX XML file ignored. Name conflicts with a previously loaded worksheet. Worksheet: XX File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41747 Record ignored in XX XML file. Matching record in first worksheet not found. Row: XX Col: 1 Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41748 XX XML file ignored. Expected %s. Row: XX Col: XX Worksheet: XX File XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41749 XX XML file ignored. Based on earlier column headers expected XX. Row: XX Col: XX Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41750 XX XML file ignored. Expected XX. Row: XX Col: XX Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41751 XX XML file ignored. Units specification must be empty. Row: XX Col: XX Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41752 XX XML file ignored. Expected "UNITS" or an empty cell. Row: XX Col: XX Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41753 Record ignored in XX file. XX Row: XX Col: XX Worksheet: XX File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41754 XX XML file ignored. After trimming the name conflicts with a previously loaded file. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41755 XX XML file ignored. Too many files. Only XX files are supported. File: XX Invalid XML file will be ignored. The default XML will be utilized.
WARNING 41769 Shear Modulus entered does not match Poisson's Ratio. Not a problem for nonisotropic materials. This message warns you that the shear modulus value that has been directly entered does not match the value that would be calculated from the entered Young's modulus and Poisson's ratio. This isn't necessarily a problem; RISA-2D is just making sure you are aware of it.
WARNING 41776 Wall Panel WPXX: Material changed to General because the given CFS material is not supported in RISA-2D. Cold Formed Steel wall panels are not available in RISA-2D. This message means that the cold formed steel wall panel(s) that came into the model have been changed to General material type. CFS walls are not available in RISA-2D, so the model is probably converted from RISA-3D. Please review and reassign wall material properties in RISA-2D before proceed, or open the model in RISA-3D to proceed with CFS wall panel design.
WARNING 41780 Solution will be cleared The solution file is not from the same version as the program currently trying to read it. The current saved solution file must be deleted to continue opening this file in the current version.
WARNING 41781 Results will be cleared This operation will cause the current results to be cleared. Performing the current action will cause the current results to be cleared.
WARNING 41785 Bar size unknown. Setting size to #3. Rebar size is unknown, program setting rebar to default #3. Choose a valid rebar size.
WARNING 41786 Bar diameter larger than XX. Setting to XX. Minimum rebar size is larger than maximum rebar size, program setting minimum rebar size to maximum rebar size. Choose a valid rebar size.
WARNING 41787 Rebar Set unknown. Setting to ASTM A615. Rebar set is unknown, program setting to default ASTM A615. Choose a valid rebar set.
WARNING 41788 Surface Load 'X' was not loaded. 'Plate' value is invalid and was not found. Surface load is not properly applied to assigned plate. Verify plate exists and is labeled correctly in the Plates Spreadsheet.